Release Notes for iCE3 FX Software ------------------------------------------------------------- Date: 1 Feb 2018 Version: 2.00 New Features 1. Allow APN to be sent via SMS message as part of remote GOL sequence request. iBETS 1740 Bug Fixes 1. Alarms don't restore if sensor is in event mode. iBETS 2046 2. Obtaining network time sync (NITZ) is not reliable. iBETS 755 ------------------------------------------------------------- Date: 1 May 2017 Version: 1.90 Bug Fixes 1. PPP session not closed at end of TCP connection sequence. iBETS 1925. 2. Totalisers should use local time, not UTC. iBETS 1963 3. FTP files appearing to not be sent. iBETS 1929 4. Optimise FTP pointer save frequency to minimise flash memory erase wear. iBETS 1996 5. Falling battery voltage alarm on start up may remain always active. iBETS 1830 ------------------------------------------------------------- Date: 1 Sep 2016 Version: 1.80 New Features 1. Received SMS handler changes to support the HyQuest GDSP. iBETS 1906 Bug Fixes 1. iCE3FX won't log YTD totaliser values. iBETS 1870 2. Packed UNIX time not being updated causes a HydroTel issue unloading standalone iCE3 FXs. iBETS 1901 3. Optimised TCP client mode communication handler to improve socket disconnection behaviour. iBETS 1657. ------------------------------------------------------------- Date: 6 May 2016 Version: 1.70 New Features 1. Added support for configuration of Active/Passive FTP Mode. iBETS 1855 NOTE: Requires iLink 2012 V4.4.21+ or HydroTel V4.22+ to configure. Bug Fixes 1. FTP data files using local time do not work correctly with negative UTC offsets on month transitions. iBETS 1863. ------------------------------------------------------------- Date: 16 Dec 2015 Version: 1.60 New Features 1. Added support for GPS active antenna power (d16 controls it). iBETS 1824 Bug Fixes 1. Connection watchdog not applied to permanent UDP mode. iBETS 1804 ------------------------------------------------------------- Date: 3 Sep 2015 Version: 1.50 Bug Fixes 1. Sending customised SMS alarm texts even if device set to IP (TCP/FTP) comms mode. iBETS 638. Resolved issue with this update (only affecting the iCE3 FX) in the previous V1.40 release. ------------------------------------------------------------- Date: 1 Jul 2015 Version: 1.40 New Features 1. Added support for sending customised SMS alarm texts even if device set to IP (TCP/FTP) comms mode. iBETS 638. Bug Fixes 1. Daily logging of totals (log rate = 1440) actually logs every minute from 00:00 to 00:59. iBETS 1686. 2. Optimised TCP client mode communication handler to improve socket disconnection behaviour. iBETS 1657. 3. Temperature compensation applied to analogue input measurement. 4. CSI (CR10) host mode not working fully. iBETS 1717. ------------------------------------------------------------- Date: 7 Aug 2014 Version: 1.30 New Features 1. GPS capability added. Only applicable to the iCE3FX GPS hardware variant. Bug Fixes 1. FTP transfer of zero length file forces module restart. iBETS 1403 2. Gaps in FTP data due to FTP channel faults. iBETS 1439. 2. Responding to SMS message after a connection request has been made will cancel the next call-in. iBETS 1438 3. Custom 'GOL,IP,port' command should always connect in IP mode, even if the defined mode is FTP or SMS. iBETS 1369 ------------------------------------------------------------- Date: 10 Jun 2014 Version: 1.20 New Features 1. Allow sensor min and max to still be logged even in "Instant" process mode. iBETS 1317. 2. Add optional software debounce filter for pulse source types controlled by sensor sample rate. iBETS 1332. ------------------------------------------------------------- Date: 2 Dec 2013 Version: 1.10 Notes: This version is the first public iCE3 FX software release. -------------------------------------------------------------